为您提供安全、经济、专业的服务

注重服务细节,提高服务品质

服务热线 :

18518172431 185-18172431

当前位置:网站首页 » 供应列表

传感器 编码器

压力传感器TUENKERS管螺纹K32 A11 T12 Z 105规格参数-直采

品牌:TUENKERS

产地:德国

规格:V50.1 A10 T12 105

¥:面议

产品详情

压力传感器TUENKERS管螺纹K32 A11 T12 Z 105规格参数-直采


分类:

TUENKERS 夹紧气缸,

TUENKERS模具,
TUENKERS冲头,
TUENKERS压力传感器,
TUENKERS接近开关,
TUENKERS压力变送器

德国TUENKERS公司 专业生产销售汽车厂焊装生产线上所用的夹紧汽缸,车身底板定位销,机器人抓手,打孔,打钢印等TUENKERS品牌的相关产品。

德国TUENKERS压力传感器机器人夹手 打钢印夹紧气缸-源头直采

V 50.1 A00 T12 90
V 50.1 A10 T12 90
V 50.1 A10 T12 90
V 50.1 A10 T12 90
V 63.1 A10 T12 90
V 63.1 A10 T12 90
V 63.1 A10 T12 90
V 63.1 A10 T12 90
V 63.1 A10 T12 90
V 63.1 A12 T12 90
V 50.1 A00 T12 90
V 63.1 A10 T12 90
V 63.1 A10 T12 90
V 63.1 A10 T12 90°
V 63.1 A11 T12 45
V 63.1 A11 T12 45
V 63.1 A11 T12 90
V 63.1 A11 T12 90
V 63.1 A12 T12 45
V 63.1 A12 T12 45
V 80.1 A10 T12 135
V50.1 A10 T12 90
V63.1 A10 T12 90
PKS 16.1 A00 T03 105°
K40.1 A10 T12 90
tuenkers 264650 压力传感器
tuenkers 264650 压力传感器
tuenkers 264650 压力传感器
tuenkers 264650 压力传感器
tuenkers 217704 V 50 T01 V 63 T01 8536 50 11 接近开关
tuenkers 264650 压力传感器
tuenkers 264650 压力传感器
tuenkers TCN-SW01-T12
tuenkers y
tuenkers ZF-40-60/HUB
tuenkers V 50.1 A00 T12 90°
tuenkers A10 FOR V50.1/A10 FOR K 50
tuenkers A10 FOR V/V2 80.1
tuenkers V80.1 BR2 A00 T12 90°
tuenkers V 50.1 A00 T12 90°
tuenkers A10 FOR V50.1/A10 FOR K 50
tuenkers A10 FOR V/V2 80.1
tuenkers V80.1 BR2 A00 T12 90°
tuenkers K2-63-A11-T12-105
tuenkers SZK40-A32-T12*40
tuenkers V2-63.1-A12-T12-45
tuenkers K50-A10-T12-135
tuenkers SZK40-A02-T12
tuenkers 225694
tuenkers 264651
tuenkers 233790
tuenkers V 40 BR2 A10 T12N 90°
tuenkers V263.1A10T12105°
TueNKERS Maschinenbau GmbH PKS 16.1 A00 T03 105Grad
TueNKERS Maschinenbau GmbH K25 A10 T12 90°
tuenkers 264650
tuenkers 233790
tuenkers K63 AS A10 T12 2*90°
tuenkers V2 40 BR2 A00 T12 090°
tuenkers V2 40 BR2 A00 T12 105°°
tuenkers V2 40 BR2 A12 T12 090°
tuenkers V2 50.1 A10 T12 030°
tuenkers V2 50.1 A10 T12 045°
tuenkers V2 50.1 A10 T12 060°
tuenkers V2 50.1 A10 T12 090°
tuenkers V2 50.1 A10 T12 105°
tuenkers V2 50.1 A12 T12 90°
tuenkers V2 50.1 A12 T12 105°
tuenkers V2 63.1 A10 T12 090°
tuenkers V2 63.1 A10 T12 105°
tuenkers V2 63.1 A11 T12 090°
tuenkers V2 63.1 A12 T12 090°
tuenkers K2 80 A10 T12 105°
tuenkers V40 BR2 A00 T12 105°
tuenkers V40 BR2 A11 T12 135°
tuenkers V40 BR2 A11 T12 090°
tuenkers V40 BR2 A12 T12 090°
tuenkers V40 BR2 A11 T12 060°
tuenkers V40 BR2 A12 T12 060°
tuenkers V50.1 A10 T12 075°tuenkers V2 40 BR2 A12 T12 060°
tuenkers K40 T12 A10 105°
tuenkers MK250.1 A90T00105o
TueNKERS Maschinenbau GmbH PKS16.1 A00 T00 105
tuenkers V40 BR2 A10 T12 90°
tuenkers V63.1 A11 T12 135°
tuenkers V63.1 A12 T12 135°tuenkers K40UZBT12A19.91.4
tuenkers K60UT12
tuenkers K60UZA30T12
tuenkers V_40.1_A52_T12_105°
tuenkers V_40.1_A52_T12_135°
tuenkers V_40.1_A52_T12_90°
tuenkers V_50.1_A11_T08T_120°
tuenkers V_50.1_A11_T12_120°
tuenkers V_50.1_A40_T12_90°
tuenkers V_50.1_A41_T12_105°
tuenkers V_50.1_A41_T12_45°
tuenkers V_50.1_A42_T12_105°
tuenkers V2_50.1_A12_T08T_45°tuenkers KS2 100.2 A01 T12 90°
tuenkers 264650
tuenkers K_16.1_Z_A17 T03 105°
tuenkers PSB 32 R T07
tuenkers PSB 40 L T07°
tuenkers K2 25 A10 T12 30°
tuenkers K2 25 A10 T12 90°
tuenkers K2 25 A11 T12 30°
tuenkers V50.1 A43 T12 135°TueNKERS Maschinenbau GmbH ZF-40-60/HUB
tuenkers V2 40 A12 T12 5-55
tuenkers V2 40 A10 T12 55-120

 压力传感器TUENKERS管螺纹K32 A11 T12 Z 105规格参数-直采

压电式传感器也广泛应用在生物医学测量中,比如说心室导管式微音器就是由压电传感器制成的,因为测量动态压力是如此普遍,所以压电传感器的应用就非常广泛。
压力传感器的技术参数

量程
0~0.5Mpa/0~200Mpa
精度
±0.25 %F·S
长期漂移
0.1% F·S
零点失调
±1% F·S/
满程失调
±1% F·S/
零点温漂
±0.05% F·S /℃
满程温漂
±0.05% F·S /℃
工作温度
-40℃ ~ +120 ℃
存储温度
-40℃ ~ +120 ℃
补偿温度
-20℃ ~ +85 ℃
工作电压
9~36VDC
电流输出
4~20mA
毫伏输出
0~5VDC
绝缘电阻
100MΩ(50VDC)
介质兼容
316SS或304不锈钢
法兰规格
DN50 PN4.0 GB9116.7-8.8 &DN80 PN4.0 GB9116.7-8.8


 压力传感器TUENKERS管螺纹K32 A11 T12 Z 105规格参数-直采

1. 压力传感器正确安装方法:
(1) 通过适当的仪表, 在普通大气压和标准温度条件下,核实压力传感器的频率反应值。
(2) 核实压力传感器的编码与相应的频率反应信号的正确性。
2. 确定具体安装位置
为了确定压力传感器的编号和具体安装位置, 需按充气网的各个充气段来考虑。
(1) 压力传感器必须沿着线缆进行安装, 最好安装在线缆接头处。
(2) 每条线缆装设压力传感器不少于4个, 靠近电话局的两个压力传感器, 相距不应大干200m。
(3) 每条线缆的始端和末端分别安装1个。
(4) 每条线缆的分支点应装1个, 如果两个分支点相距较近(小于100 m),可只装1个。
(5) 线缆敷设方式(架空、地下)改变处应装1个
(6) 对无分支的线缆, 因垒线的线缆程式一致, 压力传感器的安装隔距不大干500m, 并使其总数不少于4个。
(7) 为了便于确定压力传感器故障点, 除在起点安装压力传感器外,距起点150~200m处,还要另外安装1个当然在设计中, 一定要考虑经济与技术的因素, 在不需要安装压力传感器的地方,则应不必安装。

压力传感器TUENKERS管螺纹K32 A11 T12 Z 105规格参数-直采


在线订购

姓名
手机号
数量
电话
邮箱
单位
备注